"The most significant breach of U.S. military computers ever" is how William Lynn, the deputy secretary of defense, later described a worm that arrived on a flash drive. Someone put the drive into a U.S. military laptop at a base in the Middle East in 2008. The worm, malware that copies itself, later named Agent.btz, spread onto the laptop, and from there onto networks the military used for classified work, copying itself onto every flash drive plugged in after it.

The worm traveled on drives. Which physical control would have closed that route?
A computer whose ports are blocked can't take malware from a drive, no matter who brought the drive or what is on it. That is the job of a port blocker, a plug locked into each USB port. Turning the ports off in the laptop's settings closes the same route. The Pentagon reached for a rule instead, banning flash drives and other removable media on its computers in November 2008, and kept the ban for more than a year while it cleaned the worm out.
Cleaning Agent.btz out of the military's networks took about 14 months, in an effort the Pentagon called Operation Buckshot Yankee. Lynn said the worm had been placed by a foreign intelligence agency, though he never said which one, and some security researchers have since questioned whether it was a deliberate attack at all. The breach is one of the reasons the United States created U.S. Cyber Command, its military command for cyberspace: ordered in 2009, it began operating in 2010.
Delta's backup power
A power control module at Delta Air Lines' data center in Atlanta failed and caught fire in the early hours of August 8, 2016, eight years before the CrowdStrike outage, and the building lost its main power. Delta had backup power, yet it stopped its flights worldwide for several hours and canceled about 2,000 flights over the next three days, at a cost it put at about 150 million dollars. Why didn't the backup keep it flying?
Not every server was connected to it. Delta's chief executive, Ed Bastian, said about 300 of the company's 7,000 servers weren't wired to the backup supply, a gap that had gone unnoticed. When those 300 went dark, the systems that depended on them failed too. A backup protects only what is plugged into it.
In a data center the two work together. When the power fails, the UPS batteries take over almost at once and carry the load long enough for the generators to start. At that size, a UPS draws on a whole room of batteries wired together in long strings on racks. Delta's 300 unconnected servers had neither.

The district office's findings
The school district office from the lesson on rating physical risk has more findings than the three on its heat map. Each calls for a different control, chosen by asking how an adversary would use the weakness.
The front entrance comes first. The front desk used to buzz visitors through a single door, and whoever happened to be standing nearby walked in on the same buzz. Payroll and HR files sat behind that door, a high risk. The district rebuilt the entrance as a vestibule, a small room between two doors. The outer door stays unlocked during office hours. The inner door, into the payroll and HR offices, unlocks only after the outer door has closed, for one badge at a time, or when the front desk buzzes a visitor through. The front desk sits beside the vestibule behind a window into it, so if two people stand inside on one badge, the desk sees them and keeps the inner door locked.
A full-height turnstile does the same job with steel arms in place of a room. Each badge read frees the arms to turn just far enough for one person to pass, and then they lock until the next badge is read.

The card reader on the inner door does a second job. Every badge shown there is recorded with the time, so when the building's after-hours alarm went off one night, the log showed which badge had come through after 6 p.m. And a summer contractor's badge opens the side door to the custodial wing but not the inner one, since it isn't authorized there.
Inside, the front desk's computer, which keeps the visitor log, sits on the counter where visitors wait, and anyone standing there could carry it off. A cable lock now ties it to the desk. The district's backup generator stands beside the bus loop, open to the lot. A bus that misjudged a turn could back into it, and anyone crossing the lot at night could reach its fuel cap and controls, so a short fence and a row of steel posts now surround it.
Prioritizing the fixes
The district couldn't do everything at once. The printer that put report cards within reach of the public, rated high on the heat map, needed only a settings change, holding each job until a staff member releases it at the machine, so it went first: a high risk with an almost free fix. The front office grumbled in September that walking to the printer for every job slowed the counter, and Leah Ellery, the district's facilities director, kept the setting anyway. The generator fence and posts went in that fall. They were cheap, and the generator is the backup for every school's network. The vestibule addressed a high risk too, but it meant construction, so it waited for the next summer, when the school side of the building was empty. Repaving and relighting the staff parking lot is still waiting, an expensive job for a lot where nothing has ever gone missing.
Sources: William J. Lynn III, "Defending a New Domain," Foreign Affairs (September/October 2010); Noah Shachtman, "Insiders Doubt 2008 Pentagon Hack Was Foreign Spy Attack," Wired Danger Room (August 25, 2010); Threatpost, "Buckshot Yankee" (June 30, 2011); Army News Service on the easing of the removable-media ban (February 2010); Atlanta Journal-Constitution interview with Ed Bastian and AP coverage of the outage (August 2016); CNN Money coverage of the outage's cost (September 7, 2016).